Neohexa Sirolimus Eluting Stent

Product Description

Neohexa is a Sirolimus Eluting Cobalt Chromium Coronary Stent with unique proprietary Biodegradable polymer matrix which gives excellent coating integrity.

Neohexa is designed in a way that it maintains metal artery ratio. The design of a stent is innovative with ‘S’ link and alternate ‘C’ link. In Cobalt Chromium stents we use Sirolimus drug because Sirolimus  is a Potent anti-proliferative agent when coated on coronary stents it prevents organ re-stenosis.

With the features of Excellent and Uniform Scaffolding these devices provide short-term scaffolding of the vessel and then dissolve, which should theoretically circumvent the side effects of metal drug-eluting stents. High radial strength which makes it ideal for proximal lesions. Minimal balloon overhang which minimizes the risk of edge dissection (a procedural complication of percutaneous coronary interventions.)

A high radial strength which makes it ideal for proximal lesion

Low deflation time

No Foreshortening suitable for Ostial lesion

Minimal Balloon Overhang which minimizes the risk of edge dissection

Low recoil ensures predictable results

Excellent & uniform scaffolding

Technical Specification

Stent Feature

  • 8 Crowns for uniform and optimum vessel scaffolding
  • Inovative “S” link and alternate “C” link design
  • Superior stent strength through L605 cobalt chromium alloy
  • Thin struts (60 um)
  • Drug: sirolumus ug/mm²
  • Thin drug/ polymer coating thickness: 4-5 um
  • Crossing profile: 0.95mm (0.037″)
  • MRI compatibility: MR conditional
  • Available Size:
    Stent diameter: 2.00 tp 4.50 mm ; Stent length: 7 to 48 mm

Stent Feature

  • 8 Crowns for uniform and optimum vessel scaffolding
  • Inovative “S” link and alternate “C” link design
  • Superior stent strength through L605 cobalt chromium alloy
  • Thin struts (60 um)
  • Drug: sirolumus ug/mm²
  • Thin drug/ polymer coating thickness: 4-5 um
  • Crossing profile: 0.95mm (0.037″)
  • MRI compatibility: MR conditional
  • Available Size:
    Stent diameter: 2.00 tp 4.50 mm ; Stent length: 7 to 48 mm

No Foreshortening

NeoHexa : Low/ Minimal Foreshortening (<1%)

No Foreshortening

NeoHexa : Low/ Minimal Foreshortening (<1%)

Drug Release Kinetic

Drug Release Kinetic

Radial Strength (N/mm)

Radial Strength (N/mm)

Product Brochure

Live Chat Support

PT Dian Langgeng Pratama is dedicated to ensuring that healthcare equipment needs across Indonesia are met with the highest quality services. Contact us today to learn how we can support your needs.